Purpose and Benefits

This application/module syncs Radiology Orders from OpenMRS using AtomFeed Sync. For each Radiology Order a HL7 Message is created and sent to the Digital X-Ray Machine Modality using HAPI Library. HL7 Version 2.5 is used across the application.

  • For a Radiology Order with NEW Action, an ORM with Order Type as “NW”(Create WorkList Item) HL7 Message is created.

  • For a Radiology Order with DISCONTINUE Action, an ORM with Order Type as “CA”(Cancel WorkList Item) HL7 Message is created.   

Info
titleNote

For testing the PACS-integration setup, use the Test PACS Setup with Bahmni PACS Simulator. We have developed this to ensure easy testing as it is not always feasible to test with the Client's machine. This Simulator takes the orders and uploads a sample X-Ray to DCM4CHEE.

Steps

1. Install PACS-integration webapp

Set FACTER_deploy_bahmni_pacs environment variable to true in ~/.bashrc file and then follow the steps below.

You can install pacs-integration webapp module using either Installer(puppet) or RPM.

Using installer : Run pacs-installer.sh separately or bahmni-installer.sh would have installed pacs-integration tomcat webapp.

Using RPM : Install bahmnipacs.rpm, this will install both pacs-integration and also dcm4chee with Oviyam2

Once you are done with installing, the url http://ipaddress:8080/pacs-integration will have the module up and running with the message “PACS Integration module is up and running.” and the bahmni_pacs postgres database will be created.  


Screenshot indicating that the PACS integration module setup is successful

2. Add Procedure Codes Mapping

Bahmni will have a set of Radiology X-Ray Concepts and the Client's machine will have a set of X-Rays. We need to map both to make sure that the ordered X-Ray is properly picked at client side following PACS+procedure+code+mapping.

Data Setup

 Set up data in Modality, Order Type

,

and Markers tables in the bahmni_pacs postgres database.

-
  • Modality Table should have Client Digital X-Ray machine's HL7 Interface
ip
  • IP, port, AE Title as its name
Image Removed
  • Image Added
-
  • Order Type Table should have the
Order Type
  • same details as in
openmrs databse, respective
  • the OpenMRS databse. The Modality Id from Modality Table is used to send
those
  • the particular order type orders to the given modality.
Image Removed

Image Added

-
  • Markers Table should be set with the latest markers
,
  • and feed details.

Image Removed

For Development 

 

Image Added


Tip
iconfalse
titleOn this Page

Table of Contents
stylenone

Panel
titleColorwhite
titleBGColor#668D3C
titleFeature Details

Radiology and PACS - Feature Guide

Panel
titleColorwhite
titleBGColor#668D3C
titleUsage Details

Radiology and PACS - User Guide